摘要
Roya ZARMEHR ZAMIN 医师
医学博士
How retrograde flow (back-flow) of dermal filler injection can cause the migration of product: Ultrasound assessment
Objectives: Dermal filler injections are a cornerstone of aesthetic medicine, providing non-invasive solutions for facial contouring and rejuvenation. However, complications such as retrograde flow (back-flow) of filler material and subsequent product migration have emerged as significant concerns, potentially leading to unpredictable aesthetic outcomes and patient dissatisfaction. Despite its clinical importance, the mechanisms underlying retrograde flow and product migration remain under explored.
Introduction: This study aims to investigate how retrograde flow during filler injection contributes to the unintended migration of the product, using high-frequency ultrasound (HFUS) to visualize and analyze these phenomena. A total of [insert sample size] patients who underwent filler treatments in regions such as the lips, nasolabial folds, and tear troughs were evaluated. Ultrasound assessments were performed immediately after injection and during follow-up periods to monitor the movement of the filler material.
Materials / method: The study underscores the critical role of proper injection techniques, including low-pressure application and awareness of anatomical landmarks, in minimizing the risk of retrograde flow. HFUS proved to be an indispensable tool in detecting and tracking filler migration, offering real-time insights into the dynamics of dermal filler behavior
Results: Our findings demonstrate that retrograde flow occurs primarily when excessive injection pressure is applied, particularly in areas with high vascular density or in cases where the injector fails to maintain a controlled flow rate. This back-flow can lead to filler migration along anatomical planes, such as the facial arteries or interstitial tissue, resulting in volume shifts, contour irregularities, or nodules in unintended locations.
Conclusion: These results highlight the need for advanced injector training and advocate for the integration of ultrasound technology into routine aesthetic practice. By understanding the factors contributing to retrograde flow and migration, practitioners can improve safety, predictability, and patient satisfaction in dermal filler treatments.
披露 - Roya ZARMEHR ZAMIN
> 您是否获得了任何资金来支持您关于这个主题的研究?
不是
> 您在这项研究工作中是否获得过任何酬金、报酬或其他形式的补偿?
不是
> 您是否与任何可能与您研究中涉及的药物、材料或器械存在激烈竞争的实体有任何财务关系?
不是
> 您是否拥有或已申请过与您研究中所讨论的仪器、药物或材料相关的任何专利?
不是
这项工作没有任何直接或间接的资金支持。由作者自己承担责任。
Published on 2025年 6月 26日 - Recorded during IMCAS Americas 2025