摘要
Sho MATSUURA 医师
整形外科医师
Association between injection-plane allocation and volumetric outcome after autologous breast fat grafting
目标: 1.To evaluate the association between injection-plane allocation and postoperative volumetric gain after autologous breast fat grafting.
2.To determine whether superficial allocation is associated with lower retention after adjustment for baseline clinical factors including preoperative breast volume, total injected volume, and BMI.
3.To provide a practical framework for considering plane distribution in surgical planning to optimize volumetric outcome.
介绍: Autologous breast fat grafting is widely performed, yet volumetric retention remains variable and incompletely predictable. Injection-plane allocation—how the graft is distributed across superficial, deep, and intramuscular planes—may influence postoperative outcome, but the relationship between layer distribution and postoperative breast volume has not been adequately characterized. We investigated whether the proportion of graft placed in superficial versus deeper planes was associated with postoperative volumetric gain and retention.
材料 / 方法: We retrospectively analyzed bilateral autologous breast fat grafting cases with postoperative volumetric follow-up at 3 and 6 months. Allocation ratios were calculated for superficial and deeper planes, including intramuscular distribution. Associations between allocation pattern and volumetric outcomes were assessed using correlation analyses. Multivariable models were constructed to evaluate whether superficial allocation remained associated with retention after adjustment for preoperative bilateral breast volume, total injected volume, and body mass index.
结果: At 3 months, higher superficial allocation was associated with lower volumetric gain (rho=-0.517, p<0.001), whereas deeper allocation showed positive associations (deep-plane rho=0.418, p=0.001; intramuscular rho=0.455, p<0.001). Similar patterns were observed at 6 months (superficial rho=-0.508, p<0.001; deep-plane rho=0.498, p<0.001; intramuscular rho=0.520, p<0.001). In multivariable analyses, higher superficial allocation remained independently associated with lower retention at 3 months (p=0.008) and 6 months (p=0.006).
总结: Injection-plane allocation was associated with postoperative volumetric outcome after autologous breast fat grafting. Greater superficial allocation was associated with lower gain and lower retention, whereas deeper allocation, including intramuscular distribution, showed more favorable volumetric associations across both early and intermediate follow-up. Plane distribution may therefore represent a clinically relevant planning factor when optimizing volumetric outcome and should be considered during preoperative surgical planning.
披露 - Sho MATSUURA
> 您是否获得了任何资金来支持您关于这个主题的研究?
不是
> 您在这项研究工作中是否获得过任何酬金、报酬或其他形式的补偿?
不是
> 您是否与任何可能与您研究中涉及的药物、材料或器械存在激烈竞争的实体有任何财务关系?
不是
> 您是否拥有或已申请过与您研究中所讨论的仪器、药物或材料相关的任何专利?
不是
这项工作没有任何直接或间接的资金支持。由作者自己承担责任。
评论 (0)
加入 IMCAS 学院社群!