Objectives: Glabellar wrinkle correction, temple augmentation, nasolabial fold correction, nose augmentation are common location for hyaluronic acid filler injection
Introduction: The aim of this study was to use doppler ultrasound to determine anatomical relation between wrinkles and supratrochlear, dorsal nasal, superficial temporal and facial artery to perform safe injection
Materials / method: Hyaluronic acid filler was injected at glabellar wrinkle, temple, nasolabial fold and nose. A 2-dimensional Doppler ultrasound device (E-cube 15ex; Alpinion Co, Anyang, South Korea), offering a real-time color Doppler mode with a high-frequency (8-17 MHz) hockey-stick probe (I08-17; Alpinion), was used to identify the course and location of the supratrochlear artery, supraorbital artery, superficial temporal artery, dorsal nasal artery and facial artery
Results: No adverse effect were found
Conclusion: When perform hyaluronic acid filler injection, it is safe to use doppler ultrasound before injection
利益冲突声明
您有否接受任何资金来支持研究这个主题?
否
您是否接受过关于这项研究的任何酬金或其他报酬?
否
你是否和任何与您的研究所涉及的药物,材料或工具有密切联系的实体存在财务关系?
否
你是否拥有或者您已经为您此研究中的工具,药物或材料申请任何专利?
否
这项工作没有任何直接或间接的资金支持。由作者自己承担责任。