Objectives: To show the advantages of guided surgery for mentonian deformities over conventional surgical techniques: a comparative study.
Introduction: Genioplasty as an isolated surgical technique is a highly demanded procedure in the maxillofacial surgery area. Advances in facial reconstructive surgery have been associated with less morbidity and more predictable results. In this paper, “conventional” genioplasty and genioplasty by means of virtual surgical planning (VSP), CAD-CAM cutting guides, and patient custom-made plates are compared.
Materials / method: A descriptive observational study was designed and implemented, and 43 patients were treated, differentiating two groups according to the technique: 18 patients were treated by conventional surgery, and 25 patients were treated through virtual surgical planning (VSP), CAD-CAM cutting guides, STL models, and titanium patient-specific plates.
Results: The operation time ranged from 35 to 107 min. The mean operative time in the conventional group was 60.06 + 3.74 min.; in the custom treatment group it was 42.24 + 1.29 min (p < 0.001). In cases of chin rotation due to asymmetry, guided and personalized surgery was superior to conventional surgery (p < 0.01). The mean hospital stay was equal in both groups. A decrease in surgical complications was observed in the group undergoing VSP and customized treatment.
Conclusion: Multi-stage implementation of VSP with CAD-CAM cutting guides, STL models, and patient-specific plates increased the accuracy of the genioplasty surgery, particularly in cases of chin asymmetry, reducing operation time and potential complications.
Disclosures
Did you receive any funding to support your research for this TOPIC?
No
Were you provided with any honoraria, payment or other compensation for your work on this study?
No
Do you have any financial relationship with any entity which may closely compete with the medications, materials or instruments covered by your study?
No
Do you own or have you applied for any patents in conjunction with the instruments, medications or materials discussed in your study?
No
This work was not supported by any direct or non direct funding. It is under the author's own responsability