Objectives: Glabellar wrinkle correction, temple augmentation, nasolabial fold correction, nose augmentation are common location for hyaluronic acid filler injection
Introduction: The aim of this study was to use doppler ultrasound to determine anatomical relation between wrinkles and supratrochlear, dorsal nasal, superficial temporal and facial artery to perform safe injection
Materials / method: Hyaluronic acid filler was injected at glabellar wrinkle, temple, nasolabial fold and nose. A 2-dimensional Doppler ultrasound device (E-cube 15ex; Alpinion Co, Anyang, South Korea), offering a real-time color Doppler mode with a high-frequency (8-17 MHz) hockey-stick probe (I08-17; Alpinion), was used to identify the course and location of the supratrochlear artery, supraorbital artery, superficial temporal artery, dorsal nasal artery and facial artery
Results: No adverse effect were found
Conclusion: When perform hyaluronic acid filler injection, it is safe to use doppler ultrasound before injection
Disclosures
Did you receive any funding to support your research for this TOPIC?
No
Were you provided with any honoraria, payment or other compensation for your work on this study?
No
Do you have any financial relationship with any entity which may closely compete with the medications, materials or instruments covered by your study?
No
Do you own or have you applied for any patents in conjunction with the instruments, medications or materials discussed in your study?
No
This work was not supported by any direct or non direct funding. It is under the author's own responsability